Enable network redundancy after the VxRail deployment. Migrate the VxRail network traffic on a node from the NDC port to
both NDC and PCIe ports.
You must be able to configure the adjacent ToR switches to complete this task.
Review the network redundancy options and select the option that fits your requirements. ( see vxrail 8.0-x admin guide, section)
18KK-TOR-A# show lldp neighbors | grep vmnic
ethernet1/1/3 mrm-md-nl.mrmvxa... e4:43:4b:5e:04:f0 vmnic0
ethernet1/1/4 mrm-md-nl.mrmvxa... e4:43:4b:5e:04:f2 vmnic2
ethernet1/1/5 mrm-md-n3.mrmvxa... e4:43:4b:5e:07:90 vmnic0
ethernet1/1/6 mrm-md-n3.mrmvxa... e4:43:4b:5e:07:92 vmnic2
ethernet1/1/7 mrm-md-n2.mrmvxa... e4:43:4b:5f:84:50 vmnic0
ethernet1/1/8 mrm-md-n2.mrmvxa... e4:43:4b:5f:84:52 vmnic218KK-TOR-B# show lldp neighbors | grep vmnic
ethernet1/1/3 mrm-md-nl.mrmvxa... e4:43:4b:5e:04:f1 vmnic1
ethernet1/1/4 mrm-md-nl.mrmvxa... e4:43:4b:5e:04:f3 vmnic3
ethernet1/1/5 mrm-md-n3.mrmvxa... e4:43:4b:5e:07:91 vmnic1
ethernet1/1/6 mrm-md-n3.mrmvxa... e4:43:4b:5e:07:93 vmnic3
ethernet1/1/7 mrm-md-n2.mrmvxa... e4:43:4b:5f:84:51 vmnic1
ethernet1/1/8 mrm-md-n2.mrmvxa... e4:43:4b:5f:84:53 vmnic36. Identify a switch port that supports VxRail Network traffic.
7. Identify an unused switch port that is planned as target port to enable network redundancy.
8. To ensure the switch port that supports the VxRail network traffic after migration has a compatible configuration, perform
the following:
a. Verify that the VLANs used for VxRail networks (external management, internal management, VMware vSphere vMotion,
VMware vSAN, and guest networks) are compatible on both the switch ports.
b. Verify that the other switch port settings are compatible on both the switch ports.
c. If your final configuration reduces the number of uplinks, verify that the VLANs, and the other switch port settings are
consolidated into the target switch ports.
The following is a sample switch configuration for a source NDC port and a target PCIe port.
interface ethernet1/1/3
description VxRail-NDC-Port
no shutdown
switchport mode trunk
switchport access vlan 1386
switchport trunk allowed vlan 100-103,3939
mtu 9216
flowcontrol receive on
flowcontrol transmit off
spanning-tree port type edge
exit
9. Verify active uplink on the VMware VDS port groups post migration
10. Add uplinks to the VMware VDS